CES Therapy Conductive Gel to use with Ear Clip Electrodes

CES Therapy Conductive Gel to use with Ear Clip Electrodes


CES Electrotherapy Gel For Earclip Electrodes

Most people prefer to use the carbon ear clip electrodes with the MyoCalme CES therapy device. For this, we offer Electra 2 Oz. conductive gel made by Parker Laboratories. It may also be used on EMS/TENS cloth electrodes to add "extra life" so they will last longer.  Non-irritating, hypoallergenic & sodium free.

  • TECHNICAL SPECS
  • SHIPPING CHARGES
  • STIMTEC 4 REVIEWS

Channel:  Dual

Power Supply: AC Adapter or 9V battery

Timer: Adjustable from 1 to 60 or continuous


TENS MODE:

Waveform: Mono-phase square pulse wave

Pulse Amplitude: Adjustable from 0 to 100mA peak at 1000

Ohms load each channel: 1mA/step

Pulse Width: Adjustable from 50 to 300 𝞵s, 10𝞵s/step;

Default value is 300𝞵s

Pulse Rate: Adjustable from 1 to 150Hz, 1Hz/Step

Time: Adjustable from 1 to 60 min or continuous

4 PROGRAMS:

  • TENS/P1-TENS/Burst Mode
  • TENS/P2-TENS/Normal Mode
  • TENS/P3-TENS/Pulse Width Modulation
  • TENS/P4-TENS/Pulse Rate Modulation

EMS MODE


Waveform:  Mono-phase square pulse wave

Pulse Amplitude:  Adjustable 0 to 100 mA peak at 1000

Ohms load each channel: 1mA/step

Pulse Width:  Adjustable from 50 to 300μs

10μs/step: Default value is 300μs

Pulse Rate: Adjustable from 1 to 150Hz

1Hz/Step: Default value is 10Hz

Contraction Time: Adjustable from 1 to 30 sec.

1 sec./step: Default value is 40 sec.

Ramp Time:  Adjustable from 1 to 6 sec.

1 sec/step: Default is 5 sec.

Time: 1 to 60 min. Or continuous


EMS PROGRAMS

  • EMS/P1-EMS/Synchronous

  • EMS/P2-EMS/Alternate

  • EMS/P3-EMS/Delay


    RUSSIAN STIM MODE 2500 HZ


    Waveform: Symmetrical bi-phase square pulse wave

    Pulse Amplitude: Adjustable from 0 to 70 mA peak to peak at 1000

    Ohms load each channel: 1mA/step

    Interference Frequency:  50Hz Fixed

    Pulse Rate: Channel #1 2500Hz

    Channel #2-2550Hz

    Pulse Width:  Channel #1 200uS fixed:

    Channel #2 196uS, fixed

    Contraction Time: 1 to 30 sec., 1 sec./step. Default 10 sec.

    Relax Time: 0 to 60 sec., 1 sec./step; Default 40 sec.

    Ramp Time: 1 to 6 sec., 1 sec./step; 5 sec. Default

    Time: 1 to 60 min. Or continuous.


IF MODE:

Waveform:  Symmetrical bi-phase square pulse wave:

Pulse Amplitude: Adjustable from 0 to 70 mA peak to peak at 1000

Ohms load each channel: 1mA/step

IF: From 1 Hz to 150Hz

Pulse Rate: channel #1-fundamental frequency-4000 Hz fixed

Channel #2-selectable frequency 4001 to 4150Hz

Pulse Width: Channel #1 - 125uS fixed:

Channel #2- depends on frequency.

Cycle Time: 5 to 30 Sec. 1 sec./step: Default value is 10 sec.

Time: 1 to 60 min. Or continuous.

4 Programs


StimTec 4 orders within the USA will ship via USPS priority mail at a flat rate of $7.99.

StimTec 4 orders to Canada, Mexico and all other parts of the world will ship via DHL Express. A flat rate of $25 US Dollars will apply.